CENG 471 - Process Control Lab

 

Pulse Test 

 

 TEST PROCEDURE:

  • Specify a file name and start LabView program.
  • Set manually the water pump flow rate to 600 ml/min
  • Set the salt pump flow rate to 30 ml/min.
  • Wait for output salt concentration to stabilize.
  • Set the salt pump flow rate to 230 ml/min.
  • After approximately 9 seconds, set the salt pump flow rate back to 30 ml/min.
  • Wait for output salt concentration to stabilize.
  • Stop the LabView program.
   